PLAFONE Smoke control damper

PLAFONE

Smoke control damper

PLAFONE is a fire and smoke control tunnel damper for public access buildings, high-rises or category 3 and 4 residential buildings.
PLAFONE
Download CAD Library file
PLAFONE
PLAFONE is a fire and smoke control tunnel damper for public access buildings, high-rises or category 3 and 4 residential buildings. It can be installed in a suspended ceiling. It features the ISONE upgradable mechanism.
PLAFONE

The + products

  • minimal leak rate,
  • certified for remote installation and horizontal installation,
  • ISONE scalable mechanism.
  • wide range of approved ducts.

In standby position, the damper is closed. It opens when instructed by the FACP and moves into failsafe position.

  • CE marking compliant as per EN 12101-8: 1812 - CPD -1054,
  • fire resistance classification as per EN 1366-10 test:
    • EI 120 (ved-ho-io) S -1500 Pa - AA multi, in accordance with § 7.2.4 of EN13501-4.
  • certified up to EI 120 S on the following smoke and heat exhaust ducts (and products compliant with EN 1366-9 of the same material and same density):
    • PROMATECT L500,
    • TECNIVER L,
    • GEOFLAM / GEOFLAM Light,
    • EXTHAMAT P,
    • GLASROC F V500,
    • Desenfire,
    • STAFF PUR.
  • compliant with French standard NF-S-61937-10,
  • very low leak rate, < 200 m3/h per m² of blade at 1,500 Pa,
  • most demanding fire resistance classification: EI 120 S -1500 Pa.
  • 2 metallic sleeves,
  • drilled refractory complex for attachment in smoke exhaust duct EN 1366-8 or -9,
  • ISONE type electrical control mechanism, can accept an electromagnetic trip device, up to 4 signal contacts and an EHOP reset motor,
  • nominal X - Y dimensions of damper: dimensions of installation hole in duct,
  • more information on ISONE type mechanism in fire damper pages.
  • “multi-compartment” smoke control damper are suited to “mono-compartment” applications,
  • maximum negative pressure: - 1500 Pa,
  • fire direction: inside the smoke exhaust duct (when the damper is closed),
  • use of the CONCEPTOR DESENFUMAGE design software recommended to define the opening dimensions in the suspended ceiling,
  • nominal X and Y dimensions of damper = interior dimensions of duct,
  • insert the short 60 mm sleeve of the damper in the duct air stream,
  • attachment to the duct using screws and adhesive,
  • installation in the supporting duct must comply with CE certification, classification report available on www.aldes.fr.
Free air passage section (dm²) Insulation material

1,5 (Min) - 81,8 (Max)

PLAFONE
Lmin x Hmin (mm) Lmax x Hmax (mm)

200 x 200

1000 x 1000 / 1500 x 500

  • PV CE number  :  1812-CPR-1054

Products and accessories references

  • PLAFONE tunnel damper with choice of options
    PLAFONE tunnel damper with choice of options
    11041111
    from 1,00 (without VAT)

Documents

Showing 1 - y of document
  • Certificate of consistency of performance CE - CPR / PV FEU /PLAFONE
    Conformities
    2 MB
  • Declaration of performance (DOP) PLAFONE
    Conformities
    216 KB
  • Fire resistance rating certificate PLAFONE
    Conformities
    1 MB
  • PLAFONE Installation & maintenance instructions
    Manuals
    2 MB
  • PLAFONE - PV FEU Certificat de Constance de Performance CE - CPR
    Conformities
    2 MB

1 software