CX3000
Air handling unit
The CX3000 can be selected in a Left or Right version. Water heating coil (HW) for integration and additional coils for duct mounting can be ordered as accessories: electric heating coil (PHE), electric heating coil (AHE) and/or cooling/heating coil (COCW).
The CX3000 is controlled by the advanced EXcon control system.
The + products
- For fitting above suspended ceiling
- Highly compact for when space is limited
- Low sound or noise level
- Available in Left and Right models
- EXcon control system
- Easy to install and service
- Flexible hinges with multiple opening options
- Complies with hygiene standard VDI 6022
- 6 CX3000 models from 500 to 3 300 m3/h
- Counterflow monoblock units
- free-hanging design with double plate panels
- External finish: Aluzinc AZ185: corrosion class C4
- 50 mm mineral wool insulation, density 70 kg/m3
- EN1886 values: D2, L2/L2, T2, TB3, F9
- EC motor with high efficiency B wheel Metal/Composite
- Easy service and maintenance access: hinged doors or sliding rails for the doors as optional accessories
- High-performance heat exchanger
- Modulating bypass
- Filter options for optimised air quality.: panel filter ISO ePM10 50% (M5) or ISO ePM1 50% (F7) standard filters, option for ISO ePM1 80% (F9)
-
EXcon Control System
- Constant speed
- multi-speed
- Constant pressure
- 0–10 V
-
Configuration and monitoring via
- HMI cable for remove control
- option: Web server and BMS Communication via Modbus RTU/RS485, BACnet MSTP/BACnet IP protocol
- option: Web server and BMS Communication via bridge to Modbus TCP/IP or LON protocol
-
EXcon Control System:
- Constant speed,
- Constant airflow,
- Constant pressure,
- Air measurement control CO2/VOC sensor (0–10V signal). - Controlled pressure,
- Built-in clock: operation hours can be controlled by means of a timer,
- Remote control system via cable,
- BMS Communication via Modbus RTU and Bacnet TCP/IP protocols.
-
- Constant air speed (CAV). - Variable air speed (VAV).
- Airflow controlled - demand controlled (DCV) using CO2,/VOC sensor (0–10V signal) ,
- Option: Built-in web server,
- Option: BMS communication via Modbus RTU/RS485, Modbus TCP/IP, BACnet, MSTP/BACnet IP.
- Indoor above (false ceiling)
- Round or rectangular duct mounting
- Right and left variants
References | Insulation density (kg/m³) | Thickness of insulation (mm) | Available filters | Fluid temperature (air) | Max. Total efficiency (A-D) (%) | Efficiency level requirements | ECO efficiency level during optimal operating point | EC motor | Total pressure (Pa) | RPM during optimal operating point | Connection direction | Type of motor | Power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
11058139 - CX3010 Left | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
56,9 |
62N (2015) |
77,6N |
Med motorcontroller (VSD) |
512 |
4.710 |
Ceiling |
EC |
1x230 V + N + PE ∼ 50 Hz |
|
11058000 - CX3010 Right | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
56,9 |
62N (2015) |
77,6N |
Med motorcontroller (VSD) |
512 |
4.710 |
EC |
1x230 V + N + PE ∼ 50 Hz |
||
11058146 - CX3020 Left | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
61,7 |
62N (2015) |
82,7N |
Med motorcontroller (VSD) |
458 |
2.865 |
Ceiling |
EC |
1x230 V + N + PE ∼ 50 Hz |
11058143 - CX3020 Right | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
61,7 |
62N (2015) |
82,7N |
Med motorcontroller (VSD) |
458 |
2.865 |
Ceiling |
EC |
1x230 V + N + PE ∼ 50 Hz |
11058158 - CX3030 Left | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
65,5 |
62N (2015) |
83,6N |
Med motorcontroller (VSD) |
555 |
2.660 |
Ceiling |
EC |
1x230 V + N + PE ∼ 50 Hz |
11058157 - CX3030 Right | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
65,5 |
62N (2015) |
83,6N |
Med motorcontroller (VSD) |
555 |
2.660 |
Ceiling |
EC |
1x230 V + N + PE ∼ 50 Hz |
11058189 - CX3040 Left | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
65,6 |
62N (2015) |
82,6N |
Med motorcontroller (VSD) |
654 |
2.638 |
Ceiling |
EC |
1x230 V + N + PE ∼ 50 Hz |
11058175 - CX3040 Right | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
65,6 |
62N (2015) |
82,6N |
Med motorcontroller (VSD) |
654 |
2.638 |
Ceiling |
EC |
1x230 V + N + PE ∼ 50 Hz |
11058215 - CX3050 Left | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
69,5 |
62N (2015) |
85,9N |
Med motorcontroller (VSD) |
770 |
3.105 |
Ceiling |
EC |
3x400 V + N + PE ∼ 50 Hz |
11058196 - CX3050 Right | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
69,5 |
62N (2015) |
85,9N |
Med motorcontroller (VSD) |
770 |
3.105 |
Ceiling |
EC |
3x400 V + N + PE ∼ 50 Hz |
11058228 - CX3060 Left | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
69,5 |
62N (2015) |
85,9N |
Med motorcontroller (VSD) |
770 |
3.105 |
Ceiling |
EC |
3x400 V + N + PE ∼ 50 Hz |
11058226 - CX3060 Right | 70 |
50 |
Standard ISO ePM10 50% (M5) and ISO ePM1 50% (F7) filters (accessory filter box for ISO ePM1 80% (F9)) |
-20°C ....+35°C |
69,5 |
62N (2015) |
85,9N |
Med motorcontroller (VSD) |
770 |
3.105 |
Ceiling |
EC |
3x400 V + N + PE ∼ 50 Hz |
11058142 - CX3010 Left | 70 |
50 |
EC |
||||||||||
11058140 - CX3010 Right | 70 |
50 |
EC |
||||||||||
11058155 - CX3020 Left | 70 |
50 |
EC |
||||||||||
11058147 - CX3020 Right | 70 |
50 |
EC |
||||||||||
11058173 - CX3030 Left | 70 |
50 |
EC |
||||||||||
11058159 - CX3030 Right | 70 |
50 |
EC |
||||||||||
11058195 - CX3040 Left | 70 |
50 |
EC |
||||||||||
11058194 - CX3040 Right | 70 |
50 |
EC |
||||||||||
11058225 - CX3050 Left | 70 |
50 |
EC |
||||||||||
11058219 - CX3050 Right | 70 |
50 |
EC |
||||||||||
11058234 - CX3060 Left | 70 |
50 |
EC |
||||||||||
11058231 - CX3060 Right | 70 |
50 |
EC |
References | A (mm) | B (mm) | C (mm) | Ø connection (fresh air or exhaust) (mm) | Ø connection (discharge or air supply) (mm) | Weight (kg) | Connection h (mm) | Connection I (mm) | Connection, horisontal measurement (mm) | Connection, vertical measurement (mm) |
---|---|---|---|---|---|---|---|---|---|---|
11058139 - CX3010 Left | 1500 |
900 |
370 |
200 |
200 |
125 |
||||
11058000 - CX3010 Right | 1500 |
900 |
370 |
200 |
200 |
125 |
||||
11058146 - CX3020 Left | 1600 |
1150 |
400 |
250 |
250 |
164 |
||||
11058143 - CX3020 Right | 1600 |
1150 |
400 |
250 |
250 |
164 |
||||
11058158 - CX3030 Left | 1800 |
1500 |
480 |
230 |
300 |
550 |
||||
11058157 - CX3030 Right | 1800 |
1500 |
480 |
230 |
300 |
550 |
||||
11058189 - CX3040 Left | 2000 |
1650 |
565 |
286 |
400 |
600 |
||||
11058175 - CX3040 Right | 2000 |
1650 |
565 |
286 |
400 |
600 |
||||
11058215 - CX3050 Left | 2100 |
1650 |
580 |
325 |
400 |
600 |
||||
11058196 - CX3050 Right | 2100 |
1650 |
580 |
325 |
400 |
600 |
||||
11058228 - CX3060 Left | 2250 |
1970 |
580 |
370 |
800 |
370 |
||||
11058226 - CX3060 Right | 2250 |
1970 |
580 |
370 |
||||||
11058142 - CX3010 Left | 370 |
1500 |
900 |
200 |
200 |
127 |
||||
11058140 - CX3010 Right | 370 |
1500 |
900 |
200 |
200 |
127 |
||||
11058155 - CX3020 Left | 400 |
1600 |
1150 |
250 |
250 |
167 |
||||
11058147 - CX3020 Right | 400 |
1600 |
1150 |
250 |
250 |
167 |
||||
11058173 - CX3030 Left | 480 |
1800 |
1500 |
229 |
||||||
11058159 - CX3030 Right | 480 |
1800 |
1500 |
229 |
||||||
11058195 - CX3040 Left | 565 |
2000 |
1650 |
286 |
||||||
11058194 - CX3040 Right | 565 |
2000 |
1650 |
286 |
||||||
11058225 - CX3050 Left | 580 |
2100 |
1650 |
313 |
||||||
11058219 - CX3050 Right | 580 |
2100 |
1650 |
313 |
||||||
11058234 - CX3060 Left | 580 |
2250 |
1970 |
375 |
||||||
11058231 - CX3060 Right | 580 |
2250 |
1970 |
375 |
References | Minimum airflow | Max. airflow ErP (m³/h) | Max. airflow (m³/h) | Débit minimum (l/s) | Débit max (l/s) | Débit max ErP |
---|---|---|---|---|---|---|
11058139 - CX3010 Left | 55 |
520 |
520 |
15 |
144 |
144 |
11058000 - CX3010 Right | 55 |
520 |
520 |
15 |
144 |
144 |
11058146 - CX3020 Left | 101 |
760 |
760 |
28 |
211 |
211 |
11058143 - CX3020 Right | 101 |
760 |
760 |
28 |
211 |
211 |
11058158 - CX3030 Left | 152 |
1600 |
1680 |
42 |
467 |
444 |
11058157 - CX3030 Right | 152 |
1600 |
1680 |
42 |
467 |
444 |
11058189 - CX3040 Left | 215 |
2070 |
2150 |
60 |
597 |
575 |
11058175 - CX3040 Right | 215 |
2070 |
2150 |
60 |
597 |
575 |
11058215 - CX3050 Left | 282 |
2810 |
2820 |
78 |
781 |
780 |
11058196 - CX3050 Right | 282 |
2810 |
2820 |
78 |
781 |
780 |
11058228 - CX3060 Left | 305 |
3280 |
3395 |
85 |
943 |
911 |
11058226 - CX3060 Right | 305 |
3280 |
3395 |
85 |
943 |
911 |
11058142 - CX3010 Left | 41 |
405 |
405 |
|||
11058140 - CX3010 Right | 41 |
405 |
405 |
|||
11058155 - CX3020 Left | 83 |
830 |
830 |
|||
11058147 - CX3020 Right | 83 |
830 |
830 |
|||
11058173 - CX3030 Left | 145 |
1370 |
1445 |
|||
11058159 - CX3030 Right | 145 |
1370 |
1445 |
|||
11058195 - CX3040 Left | 213 |
2070 |
2130 |
|||
11058194 - CX3040 Right | 213 |
2070 |
2130 |
|||
11058225 - CX3050 Left | 323 |
2770 |
3230 |
|||
11058219 - CX3050 Right | 323 |
2770 |
3230 |
|||
11058234 - CX3060 Left | 388 |
3760 |
3880 |
|||
11058231 - CX3060 Right | 388 |
3760 |
3880 |
References | Max. exchanger output (%) | Max. current absorbed (kW) |
---|---|---|
11058139 - CX3010 Left | 94 |
3,4 |
11058000 - CX3010 Right | 94 |
3,4 |
11058146 - CX3020 Left | 94 |
4,2 |
11058143 - CX3020 Right | 94 |
4,2 |
11058158 - CX3030 Left | 94 |
5 |
11058157 - CX3030 Right | 94 |
5 |
11058189 - CX3040 Left | 94 |
7 |
11058175 - CX3040 Right | 94 |
7 |
11058215 - CX3050 Left | 94 |
4 |
11058196 - CX3050 Right | 94 |
4 |
11058228 - CX3060 Left | 94 |
4 |
11058226 - CX3060 Right | 94 |
4 |
11058142 - CX3010 Left | 94 |
3 |
11058140 - CX3010 Right | 94 |
3 |
11058155 - CX3020 Left | 94 |
2,8 |
11058147 - CX3020 Right | 94 |
2,8 |
11058173 - CX3030 Left | 94 |
6,2 |
11058159 - CX3030 Right | 94 |
6,2 |
11058195 - CX3040 Left | 94 |
7,2 |
11058194 - CX3040 Right | 94 |
7,2 |
11058225 - CX3050 Left | 94 |
4,8 |
11058219 - CX3050 Right | 94 |
4,8 |
11058234 - CX3060 Left | 94 |
4,8 |
11058231 - CX3060 Right | 94 |
4,8 |
References | Frequency (Hz) | Protection rating | Max. power of electrical coil 1 (kW) | Max. electrical output of unit (kW) | Voltage (V) | Unit voltage (V) | Max. power of electrical coil 2 | Maximum current - unit (A) | Max. power | Power consumption (kW) |
---|---|---|---|---|---|---|---|---|---|---|
11058139 - CX3010 Left | 50 |
IP20 |
3 |
0,452 |
1x230 |
3,4 |
0,15 |
|||
11058000 - CX3010 Right | 50 |
IP20 |
3 |
0,452 |
1x230 |
3,4 |
0,15 |
|||
11058146 - CX3020 Left | 50 |
IP20 |
5 |
0,56 |
1x230 |
4,2 |
0,16 |
|||
11058143 - CX3020 Right | 50 |
IP20 |
5 |
0,56 |
1x230 |
4,2 |
0,16 |
|||
11058158 - CX3030 Left | 50 |
IP20 |
8 |
1,12 |
1x230 |
4 |
5,0 |
0,52 |
||
11058157 - CX3030 Right | 50 |
IP20 |
8 |
1,12 |
1x230 |
4 |
5,0 |
0,52 |
||
11058189 - CX3040 Left | 50 |
IP20 |
11 |
1,58 |
1x230 |
5,5 |
7,0 |
0,768 |
||
11058175 - CX3040 Right | 50 |
IP20 |
11 |
1,58 |
1x230 |
5,5 |
7,0 |
0,768 |
||
11058215 - CX3050 Left | 50 |
IP20 |
14 |
2,32 |
3x400 |
7 |
4,0 |
1,06 |
||
11058196 - CX3050 Right | 50 |
IP20 |
14 |
2,32 |
3x400 |
7 |
4,0 |
1,06 |
||
11058228 - CX3060 Left | 50 |
IP20 |
18 |
2,32 |
3x400 |
9 |
4,0 |
1,06 |
||
11058226 - CX3060 Right | 50 |
IP20 |
18 |
2,32 |
3x400 |
9 |
4,0 |
1,06 |
||
11058142 - CX3010 Left | 50 |
IP20 |
3 |
230 |
3,0 |
0,42 |
||||
11058140 - CX3010 Right | 50 |
IP20 |
3 |
230 |
3,0 |
0,42 |
||||
11058155 - CX3020 Left | 50 |
IP20 |
5 |
230 |
2,8 |
0,68 |
||||
11058147 - CX3020 Right | 50 |
IP20 |
5 |
230 |
2,8 |
0,68 |
||||
11058173 - CX3030 Left | 50 |
IP20 |
8 |
230 |
4 |
6,2 |
1,016 |
|||
11058159 - CX3030 Right | 50 |
IP20 |
8 |
230 |
4 |
6,2 |
1,016 |
|||
11058195 - CX3040 Left | 50 |
IP20 |
11 |
230 |
5,5 |
7,2 |
1,62 |
|||
11058194 - CX3040 Right | 50 |
IP20 |
11 |
230 |
5,5 |
7,2 |
1,62 |
|||
11058225 - CX3050 Left | 50 |
IP20 |
14 |
400 |
7 |
4,8 |
2,86 |
|||
11058219 - CX3050 Right | 50 |
IP20 |
14 |
400 |
7 |
4,8 |
2,86 |
|||
11058234 - CX3060 Left | 50 |
IP20 |
18 |
400 |
9 |
4,8 |
2,86 |
|||
11058231 - CX3060 Right | 50 |
IP20 |
18 |
400 |
9 |
4,8 |
2,86 |
The cabinet is made of 0.8-mm galvanised steel corrosion class C4 in accordance with EN/ISO12944-2and insulated with 50 mm mineral wool. This results in low noise emissions to the surrounding environment.
Heat recovery occurs via a counterflow heat exchanger in aluminium with a very high efficiency. (Without condensation 80-85%, with condensation up to 95%). The integrated bypass has multiple functions:
- When heat recovery is not desired, the outdoor air is directed outside the heat exchanger
- If night cooling is desired, the outdoor air is directed outside the heat exchanger
- In case of freezing of the heat exchanger, the outdoor air is directed outside the heat exchanger so that the exchanger can thaw. The supply air (outdoor air) then requires extra heating capacity via the reheater – the reheater is a prerequisite for the system to function continuously
The motors are of type EC and are extremely efficient. They comply with the requirements of the Ecodesign Directive.
Products and accessories references
Documents
-
CX3000 Regulation manualManuals18 MB
-
CX3000 Electrical installation guideManuals1 MB
-
CX3000 Installation instructionsManuals27 MB
-
CX3000 Alarm List NoticeManuals910 KB
-
CX3010-3020 Wiring instructionsManuals2 MB
-
CX3030-3040 Wiring instructionsManuals3 MB
-
CX3050-3060 Wiring instructionsManuals3 MB