ECTA 200
ECTA 200
The ECTA 200 rectangular sound attenuator strongly attenuates low, mid and high-frequency acoustic propagation in rectangular ducting.
ECTA 200
The ECTA 200 rectangular sound attenuator strongly attenuates noise transmitted in the ventilation ducting and therefore ensures acoustic comfort inside non-residential and multi-occupancy residential buildings. The baffle is 200 mm thick and its L x H dimensions may be between 300 and 2400 mm.
The ECTA 200 comprises a single-piece panel made of 200 mm thick mineral wool which absorbs noise. To maximise attenuation, several should be installed in series inside a ducting element.
- thickness 200 mm,
- dimensions (L and H) from 300 to 2400 mm.
- solid mineral wool panels,
- density: 40 kg/m3,
- black anti-flocking glass mat, 1 mm thick in standard range (available on request: glass fibre for sterile rooms or perforated plate for high pressure and speed applications),
- galvanised steel frame, standard thickness 6/10° (available on request: 304 or 316L stainless steel),
- Available on request: complete unit including the housing, riveted baffles and METU type connection frame,
- M0 fire certification, or A1 under Euroclass ratings,
- version tested to 400°C - 2 hours on request.
- Class B air tight properties as per EN 1751 (class C on request).
- installed in series in a rectangular ducting element,
- install between slides for better performance management,
- Delivered as complete unit (on request).
References | Insulation density of the baffle (kg/m³) | Insulation thickness of the baffle (mm) | Insulation material |
---|---|---|---|
11094702 - ECTA 200 L/H 300-1399 mm | 55 |
200 |
|
11094704 - ECTA 200 L/H 1400-1999 mm | 55 |
200 |
|
11094706 - ECTA 200 L/H 2000-2400 mm | 55 |
200 |
|
11094627 - ECTA 200 L<=2000 and H<=1200 or L<=1200 and H<=2000 | 40 |
200 |
|
11094628 - ECTA 200 L>2000 or H>2000 or L>1200 and H>1200 | 40 |
100 |
References | H (mm) | L (mm) |
---|---|---|
11094702 - ECTA 200 L/H 300-1399 mm | 300-1399 |
300-1399 |
11094704 - ECTA 200 L/H 1400-1999 mm | 1400-1999 |
1400-1999 |
11094706 - ECTA 200 L/H 2000-2400 mm | 2000-2400 |
2000-2400 |
11094627 - ECTA 200 L<=2000 and H<=1200 or L<=1200 and H<=2000 | ||
11094628 - ECTA 200 L>2000 or H>2000 or L>1200 and H>1200 |
References | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 1000 Hz and inset of 100 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 1000 Hz and inset of 150 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 1000 Hz and inset of 200 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 1000 Hz and inset of 50 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 125 Hz and inset of 100 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 125 Hz and inset of 150 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 125 Hz and inset of 200 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 125 Hz and inset of 50 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 2000 Hz and inset of 100 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 2000 Hz and inset of 150 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 2000 Hz and inset of 200 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 2000 Hz and inset of 50 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 250 Hz and inset of 100 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 250 Hz and inset of 150 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 250 Hz and inset of 200 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 250 Hz and inset of 50 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 4000 Hz and inset of 100 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 4000 Hz and inset of 150 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 4000 Hz and inset of 200 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 4000 Hz and inset of 50 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 500 Hz and inset of 100 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 500 Hz and inset of 150 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 500 Hz and inset of 200 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 500 Hz and inset of 50 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 63 Hz and inset of 100 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 63 Hz and inset of 150 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 63 Hz and inset of 200 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 63 Hz and inset of 50 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 8000 Hz and inset of 100 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 8000 Hz and inset of 150 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 8000 Hz and inset of 200 mm (dB) | Acoustic attenuation measured according to standard ISO 7235 for L=1000 mm at 8000 Hz and inset of 50 mm (dB) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
11094702 - ECTA 200 L/H 300-1399 mm | 39 |
29 |
23 |
59 |
8 |
6 |
5 |
12 |
40 |
27 |
17 |
50 |
18 |
14 |
11 |
25 |
26 |
17 |
11 |
41 |
28 |
24 |
21 |
34 |
6 |
5 |
4 |
7 |
20 |
14 |
10 |
31 |
11094704 - ECTA 200 L/H 1400-1999 mm | ||||||||||||||||||||||||||||||||
11094706 - ECTA 200 L/H 2000-2400 mm | ||||||||||||||||||||||||||||||||
11094627 - ECTA 200 L<=2000 and H<=1200 or L<=1200 and H<=2000 | ||||||||||||||||||||||||||||||||
11094628 - ECTA 200 L>2000 or H>2000 or L>1200 and H>1200 |
References | Fire protection rating |
---|---|
11094702 - ECTA 200 L/H 300-1399 mm | A1 |
11094704 - ECTA 200 L/H 1400-1999 mm | A1 |
11094706 - ECTA 200 L/H 2000-2400 mm | A1 |
11094627 - ECTA 200 L<=2000 and H<=1200 or L<=1200 and H<=2000 | |