OPTONE� "+ Grille" 2 flaps
OPTONE� "+ Grille" 2 flaps
OPTONE “+Grille” smoke control dampers are intended for commercial premises and can be used as air inlets or for smoke and heat exhaust.
OPTONE� "+ Grille" 2 flaps
OPTONE “+Grille” 2-flap smoke control dampers are intended for non-residential buildings (public-access, high-rise), and can be used as air inlets or for smoke and heat exhaust. They can be motorised. OPTONE "+ Grille" 2-flap dampers include a grille which eliminates the requirement to install a separate grille. The electromagnetic trip device is included and available in current make/break versions and 24/48V.
The + products
- simplicity: Nominal dimensions = installation dimensions,
- reversible top/bottom mounting frame,
- single mounting frame for all OPTONE models.
- pre-drilled cable through holes,
- 1-flap/2-flap dampers can be motorised,
- new: core locking clip.
In standby position, the damper is closed. It opens when instructed by the FACP and moves into failsafe position.
- CE marking compliant as per EN 12101-8: Certificate 1812-CPR-1053,
-
fire resistance classification as per EN 1366-10 test:
- EI 90 (ved-i o) S - 1000 Pa - AA multi, in accordance with § 7.2.4 of
EN 13501-4 certified on Promatect smoke exhaust duct L500 and on ducts compliant with EN 1366-9 of the same material and same density,
-
- EI 60 S for H > 1000.
- compliant with French standard NF-S-61937-10,
- leak rate < 200 m3/h per m² of leaf at 1,000 Pa,
- pressure losses damper only (with grille):
-
- return: ∆p=2,083 .√(S_free/(LxH)).(Q/S_free)²,
- supply: ∆p=2,00 .√(S_free/(LxH)).(Q/S_free)²,
- ∆p in Pa, S_free m2, Q in m³.s-1, L and H in mm.
- free air passage (dm²): 2 flap = ((L-76) x (H-57) -14 147) / 10 000.
- motorised damper possible,
- electric control mechanism inside protective box,
- steel mounting frame 20/10 mm,
- grille frame attached to damper,
- nominal dimensions of damper L x H = installation space (opening) for mounting frame, attached without mortar seal,
- locking system mounted on flap for greater free surface,
- cable through holes included,
- locking system fitted with self-resetting electromagnetic trip device,
- scalable junction box,
-
available options:
- galvanised steel trim, choice of RAL colour,
- lockable core,
- backdraft (required on air intakes if speed in ducts is above 7 m/s),
- mounting frame can be installed in factory.
- “multi-compartment” dampers are suitable for “single-compartment” applications,
- maximum negative pressure: - 1,000 Pa,
- direction of fire: inside smoke exhaust duct (when damper is closed).
- use of mounting frame strongly recommended,
- use of CONCEPTOR DESENFUMAGE design software recommended to define the dimensions of the mounting frame installation space,
- if mounting frame already fixed to damper (no gaps), nominal LxH dimensions of damper = dimensions of opening,
- if mounting frame mortar sealed, add thickness of mortar to L and H,
- use detailed instructions for correct installation of flaps,
- damper can be inverted “upside down”,
- damper flush-mounted against vertical smoke exhaust duct,
- attached with 4 self-tapping screws supplied, on front face in mounting frame holes.
Free air passage section (dm²) | Insulation material |
---|---|
7,7 (Min) - 104,2 (Max) |
- PV CE number : 1812-CPR-1053
Products and accessories references
Documents
Showing 1 - y of
document
-
Certificate of consistency of performance CE - CPR / PV FEU / OPTONE® "+GrilleConformities4 MB
-
Laboratory assessment OPTONE on concrete ductConformities700 KB
-
Declaration of performance (DOP) OPTONE® "+ GrilleConformities224 KB
-
Fire resistance rating certificate OPTONE® "+Grille" 2VConformities1 MB
-
OPTONE® Moteur LOCKTONE et Kit anti-retour Installation instructionsManuals1 MB
-
OPTONE® Installation instructions, MaintenanceManuals3 MB
-
OPTONE® +Grille - Certificat de Constance de Performance CE - CPR / PV FEUConformités4 MB