DESIGN
The + products
- ultra-flat design,
- available with presence detection,
- very quiet: as low as 26 dB(A).
- available with presence detection can be installed in rooms larger than 12 m² with the 150 mm diameter
DESIGN intermittent extractors deliver intermittent ventilation of a space: bathroom, WC, laundry room or large kitchens (depending on the diameter chosen).
4 operating modes:
-
- switch-operated start/stop (version I),
- switch-operated start and adjustable timer-controlled stop (T version)
- activation by detection of humidity level, adjustable timer-controlled stop (H version),
- activation by detection of occupancy, adjustable timer-controlled stop (P version),
-
3 diameters:
- Ø 100 mm for rooms up to 7 m²; bathroom, WC, laundry room,
- Ø 125 mm for rooms from 7 to 12 m²: kitchen, bathroom, WC, laundry room,
- Ø 150 mm for rooms larger than 12 m²: large kitchen and large bathroom
-
3 operating modes:
- Switch-operated start/stop (version I),
- Switch-operated start and adjustable timer-controlled stop (version T),
- activation by detection of humidity level, adjustable timer-controlled stop (H version),
- activation by detection of occupancy, adjustable timer-controlled stop (P version),
- Low-consumption motor with low noise level,
- removable backdraft damper at rear of fan,
- built-in thermal protection,
-
material:
- high quality ABS body,
- decorative ABS cover with aluminium trim (for aluminium finish).
- supplied in a display carton.
- manual operation (version I): instant switch-operated start and stop (switch not supplied),
-
timer-controlled operation with adjustable timer (T version):
- switch-operated start,
- timer-controlled shutdown, adjustable from 2 to 30 minutes.
-
automatic operation with humidity detection (H version):
- activation of boost mode by humidity level, adjustable between 60% and 90%. Activation is automatic if the ambient humidity level exceeds the preset threshold value,
- timer-controlled shutdown adjustable between 2 and 30 minutes. Once the indoor humidity level has returned to below the activation threshold, the extractor operates for the pre-set duration then automatically shuts down.
-
automatic operation with occupancy detection (P version):
- activation by detection of occupancy,
- lens detection distance: 1 to 4 metres,
- lens detection angle: 100°,
- Timer-controlled shutdown, adjustable from 2 to 30 minutes.
- attachment using 4 screws supplied,
- wall or ceiling attachment,
- maximum length of output duct: 2 m,
- manual and timed stop-start operation using a switch,
- fresh air brought into room via air inlet grille or door undercut.
References | Surface-mounted thickness (mm) | Operation | Number of speeds | Maximum extract air temperature (°C) | Insulation material | Type of finish | Type of motor |
---|---|---|---|---|---|---|---|
11022300 - DESIGN 100 | 17 |
Manual start/stop by switch |
1 |
40 |
White |
AC |
|
11022301 - DESIGN 100 T | 17 |
Manual start by switch and timer-controlled stop |
1 |
40 |
White |
AC |
|
11022302 - DESIGN 100 H | 17 |
Automatic start by detection of humidity level, timer-controlled stop |
1 |
40 |
White |
AC |
|
11022303 - DESIGN 100 P | 17 |
Automatic start by occupancy detection, timer-controlled stop |
1 |
40 |
White |
AC |
|
11022304 - DESIGN 125 | 17 |
Manual start/stop by switch |
1 |
40 |
White |
AC |
|
11022305 - DESIGN 125 T | 17 |
Manual start by switch and timer-controlled stop |
1 |
40 |
White |
AC |
|
11022306 - DESIGN 125 H | 17 |
Automatic start by detection of humidity level, timer-controlled stop |
1 |
40 |
White |
AC |
|
11022307 - DESIGN 125 P | 17 |
Automatic start by occupancy detection, timer-controlled stop |
1 |
40 |
White |
AC |
|
11022308 - DESIGN 150 | 19 |
Manual start/stop by switch |
1 |
40 |
White |
AC |
|
11022309 - DESIGN 150 T | 19 |
Manual start by switch and timer-controlled stop |
1 |
40 |
White |
AC |
|
11022310 - DESIGN 150 H | 19 |
Automatic start by detection of humidity level, timer-controlled stop |
1 |
40 |
White |
AC |
|
11022311 - DESIGN 150 P | 19 |
Automatic start by occupancy detection, timer-controlled stop |
1 |
40 |
White |
AC |
References | A (mm) | C (mm) | D (mm) | E (mm) | H (mm) | L (mm) | P (mm) | Ø discharge (mm) | Weight (kg) |
---|---|---|---|---|---|---|---|---|---|
11022300 - DESIGN 100 | 150 |
13,5 |
85 |
17 |
150 |
150 |
115,5 |
100 |
0,56 |
11022301 - DESIGN 100 T | 150 |
13,5 |
85 |
17 |
150 |
150 |
115,5 |
100 |
0,56 |
11022302 - DESIGN 100 H | 150 |
13,5 |
85 |
17 |
150 |
150 |
115,5 |
100 |
0,56 |
11022303 - DESIGN 100 P | 150 |
13,5 |
85 |
17 |
150 |
150 |
115,5 |
100 |
0,56 |
11022304 - DESIGN 125 | 176 |
13,5 |
87 |
17 |
176 |
176 |
117,5 |
125 |
0,73 |
11022305 - DESIGN 125 T | 176 |
13,5 |
87 |
17 |
176 |
176 |
117,5 |
125 |
0,73 |
11022306 - DESIGN 125 H | 176 |
13,5 |
87 |
17 |
176 |
176 |
117,5 |
125 |
0,73 |
11022307 - DESIGN 125 P | 176 |
13,5 |
87 |
17 |
176 |
176 |
117,5 |
125 |
0,73 |
11022308 - DESIGN 150 | 205 |
13,5 |
105 |
19 |
205 |
205 |
137,5 |
150 |
0,9 |
11022309 - DESIGN 150 T | 205 |
13,5 |
105 |
19 |
205 |
205 |
137,5 |
150 |
0,9 |
11022310 - DESIGN 150 H | 205 |
13,5 |
105 |
19 |
205 |
205 |
137,5 |
150 |
0,9 |
11022311 - DESIGN 150 P | 205 |
13,5 |
105 |
19 |
205 |
205 |
137,5 |
150 |
0,9 |
References | Max. airflow (m³/h) |
---|---|
11022300 - DESIGN 100 | 70 |
11022301 - DESIGN 100 T | 70 |
11022302 - DESIGN 100 H | 70 |
11022303 - DESIGN 100 P | 70 |
11022304 - DESIGN 125 | 115 |
11022305 - DESIGN 125 T | 115 |
11022306 - DESIGN 125 H | 115 |
11022307 - DESIGN 125 P | 115 |
11022308 - DESIGN 150 | 235 |
11022309 - DESIGN 150 T | 235 |
11022310 - DESIGN 150 H | 235 |
11022311 - DESIGN 150 P | 235 |
References | Sound pressure at 3 m (dB(A)) |
---|---|
11022300 - DESIGN 100 | 26 |
11022301 - DESIGN 100 T | 26 |
11022302 - DESIGN 100 H | 26 |
11022303 - DESIGN 100 P | 26 |
11022304 - DESIGN 125 | 31 |
11022305 - DESIGN 125 T | 31 |
11022306 - DESIGN 125 H | 31 |
11022307 - DESIGN 125 P | 31 |
11022308 - DESIGN 150 | 33 |
11022309 - DESIGN 150 T | 33 |
11022310 - DESIGN 150 H | 33 |
11022311 - DESIGN 150 P | 33 |
References | Frequency (Hz) | Protection rating | Protection current (A) | Voltage (V) | Max. power |
---|---|---|---|---|---|
11022300 - DESIGN 100 | 50 |
2 |
230 |
5,6 |
|
11022301 - DESIGN 100 T | 50 |
2 |
230 |
5,6 |
|
11022302 - DESIGN 100 H | 50 |
2 |
230 |
5,6 |
|
11022303 - DESIGN 100 P | 50 |
2 |
230 |
5,6 |
|
11022304 - DESIGN 125 | 50 |
2 |
230 |
9,3 |
|
11022305 - DESIGN 125 T | 50 |
2 |
230 |
9,3 |
|
11022306 - DESIGN 125 H | 50 |
2 |
230 |
9,3 |
|
11022307 - DESIGN 125 P | 50 |
2 |
230 |
9,3 |
|
11022308 - DESIGN 150 | 50 |
2 |
230 |
20 |
|
11022309 - DESIGN 150 T | 50 |
2 |
230 |
20 |
|
11022310 - DESIGN 150 H | 50 |
2 |
230 |
20 |
|
11022311 - DESIGN 150 P | 50 |
2 |
230 |
20 |
- Text ErP - Ventilation : Complies with eco-design Regulation 1253/2014 and excluded from energy labelling Regulation 1254/2014 as maximum power is below 30 W.
Electrical insulation class |
---|
Class 2 |