Acoustic and Aeraulic T-piece branch connector: CP2A Aluminium Connector

Acoustic and Aeraulic T-piece branch connector: CP2A Aluminium

Connector

The CP2A aluminium branch connector provides a junction and accessibility to the vertical collector system and horizontal ducting, while improving acoustic and aeraulic performance.
Acoustic and Aeraulic T-piece branch connector: CP2A Aluminium
Acoustic and Aeraulic T-piece branch connector: CP2A Aluminium
The aluminium acoustic and aeraulic T-piece branch connector is an aluminium accessory used to join the vertical collector system and horizontal ducting while enabling accessibility to the vertical riser and horizontal ducting as per the requirements of DTU 68.1 and 68.2. It is specifically designed for gas CMEV risers opening out into attics or flat roofs of commercial and multi-occupancy residential buildings, for which the airtight reading is made before the T-piece is installed (> 95% of cases). The CP2A aluminium T-piece acoustic and aeraulic branch connector is fitted with a stop ring on the unit body to hold the plug in a stable position and limit the risk of leaks. The aeraulic properties of the CP2A T-piece branch connector reduce the negative pressure required for the fan and enable the use of less powerful fans, which generate less noise and consume less energy. To reduce system pressure losses, improve the operation of gas boilers and fully attenuate fan noise, use CP2A in priority for system design.
Acoustic and Aeraulic T-piece branch connector: CP2A Aluminium

The + products

  • exclusive CP2A (ALDES patent): ideal for gas CMEV,
  • 35% less pressure loss compared to a standard CP,
  • improved noise attenuation: 7 dB(A) on noise radiated from the fan (3 dB(A) better than a standard CP connector).
  • riser remains accessible.
  • range available from diameter 125 to 450.
  • performance of CP2A compared to standard CP connector:
    • acoustic: acoustic foam B-s1,d0 offering high attenuation of fan noise (by 7 dB(A), or 3 dB(A) better than a standard CP),
  • aeraulic: aluminium sheet deflection offering tool-free removal, reducing pressure losses by 35% or -7 Pa at 4 m/s.
  • aluminium 1050A-H18 (formerly A5) compliant with DTU 68.3 for gas CMEV,
  • material compliant with requirements of DTU 68.3: 2013-06 P1-1: “Mechanical Ventilation Installations”,
  • M0 fire certification.
  • easy assembly of interlocking accessories: ducts are female, accessories are male,
  • Final seal requires sealant and/or perforated strip,
  • attached to duct using self-tapping screws (4 to 6 depending on diameter),
  • if the air tightness reading is made after the T-piece connector is installed, use a CPT or CPT2A,
  • installation requires a flat roof penetration sleeve: FT.
Insulation material
Acoustic and Aeraulic T-piece branch connector: CP2A Aluminium
References L (mm) Ø A (mm) Ø B (mm) Weight (kg)
11095800 - CP T-PIECE 2A ALU - D125/200

285

125

200

10,1

11095801 - CP T-PIECE 2A ALU - D160/250

320

160

250

1,6

11095802 - CP T-PIECE 2A ALU - D200/315

350

200

315

2,67

11095803 - CP T-PIECE 2A ALU - D250/355

400

250

355

3,4

11095804 - CP T-PIECE 2A ALU - D315/400

400

315

400

3,9

11095805 - CP T-PIECE 2A ALU - D355/500

650

355

500

8,2

11095806 - CP T-PIECE 2A ALU - D400/560

650

400

560

10,35

11095807 - CP T-PIECE 2A ALU - D450/630

650

450

630

12,1

Fire protection rating

M0

  • to install a deflector in an existing CP T-piece:
    • identify the type of T-piece installed: header diameter, external diameter (often marked on plug),
    • use the appropriate deflector for the T-piece installed,
    • remove the plug,
    • position the lower part of the deflector on the bottom of the T-piece (galvanised part in contact with the airflow),
    • bend the deflector to insert the upper part in the connector,
    • replace the plug and ensure the seal is airtight.
  • to remove a deflector for header servicing access:
    • remove the plug,
    • grasp and press the upper part of the deflector then withdraw it from the T-piece,
    • remove the deflector and perform servicing operations,
    • re-position the lower part of the deflector on the bottom of the T-piece (galvanised part in contact with the airflow),
    • bend the deflector to insert the upper part in the connector,
    • replace the plug and ensure the seal is airtight.

Products and accessories references

  • CP T-PIECE 2A ALU - D125/200
    CP T-PIECE 2A ALU - D125/200
    11095800
    146,00 (without VAT)
  • CP T-PIECE 2A ALU - D160/250
    CP T-PIECE 2A ALU - D160/250
    11095801
    198,00 (without VAT)
  • CP T-PIECE 2A ALU - D200/315
    CP T-PIECE 2A ALU - D200/315
    11095802
    215,00 (without VAT)
  • CP T-PIECE 2A ALU - D250/355
    CP T-PIECE 2A ALU - D250/355
    11095803
    272,00 (without VAT)
  • CP T-PIECE 2A ALU - D315/400
    CP T-PIECE 2A ALU - D315/400
    11095804
    326,00 (without VAT)
  • CP T-PIECE 2A ALU - D355/500
    CP T-PIECE 2A ALU - D355/500
    11095805
    446,00 (without VAT)
  • CP T-PIECE 2A ALU - D400/560
    CP T-PIECE 2A ALU - D400/560
    11095806
    548,00 (without VAT)
  • CP T-PIECE 2A ALU - D450/630
    CP T-PIECE 2A ALU - D450/630
    11095807
    681,00 (without VAT)