OPTONE®-H "+Grille

OPTONE®-H "+Grille

The OPTONE-H "+ Grille” damper is used for smoke and heat exhaust on ducting in residential buildings in categories 3B or 4.
OPTONE®-H "+Grille
OPTONE®-H "+Grille
The OPTONE-H "+ Grille” damper is used for smoke and heat exhaust on ducting in residential buildings in categories 3B or 4. It is ideal for installation in a standard 400x500 mm duct (20 dm²). The OPTONE-H "+ Grille” damper features a 24V current-make trigger mechanism. However it is not fitted with signal contacts and is unable to receive them.
OPTONE®-H "+Grille

The + products

  • metal trim, aesthetic and vandal-proof,
  • shallow articulation range,
  • simplified cable inputs and outputs.
  • aesthetic grille with removable core,
  • national stock for short delivery times,
  • individually packed,
  • aesthetic electrical protective trim.

The damper is closed in standby position. It opens when instructed by the ORDONE control panel, then moves into safety position.

  • CE marking compliant as per EN 12101-8.
  • free air passage of 20.3 dm2,
  • first smoke control damper certified EI 60 S compliant with European standard NF EN 1366-10,
  • identical damper for smoke and heat exhaust (VH) and air inlet (VB),
  • 1-hour fire resistant in accordance with decision of 31 January 1986. Ideal for installation on standard duct 400 x 500 mm,
  • electromagnetic trip device VDS 24 V DC auto-reset,
  • mounting frame can be installed in factory,
  • cable through holes included,
  • grille with removable core,
  • connection terminal block: protected by a plastic cover,
  • individually packed,
  • for a damper fitted with signalling contacts, use the OPTONE T damper range.
  • mounting frame:
    • galvanised steel 20/10 mm,
    • suited for installation on concrete and on lightweight materials such as Promatect, Supalux

or Tecniver,

    • drilled to enable passage of electric cables,
    • fitted with sealing lugs and holes to receive damper screws.
    • top/down reversible,
    • 70 mm depth for good mechanical strength.
  • installation direction: “fire in the duct”,
  • surface-mounted on a smoke and heat exhaust duct CF 1h fire rating
  • attachment of OPTONE-H "+ Grille" on mounting frame recommended,
  • install the OPTONE-H "+ Grille” with the clips at the top to installed the fin core:
    • at the bottom for a VB damper,
    • at the top for a VH damper.
  • for installation with mortar-sealed mounting frame on concrete duct, add at least 100 mm for mortar,
  • for other dimensions use the OPTONE range.

Products and accessories references

Documents

Showing 1 - y of document
  • Certificate of consistency of performance CE - CPR / PV FEU / OPTONE® "+Grille
    Conformities
    2 MB
  • Laboratory assessment OPTONE on concrete duct
    Conformities
    700 KB
  • Declaration of performance (DOP) OPTONE® "+ Grille
    Conformities
    224 KB
  • Fire resistance rating certificate OPTONE® "+Grille" 1V
    Conformities
    2 MB
  • OPTONE®-H Installation & maintenance instructions
    Manuals