AXONE Micro III 1-speed/DES: 2 speeds for smoke and heat exhaust

AXONE Micro III 1-speed/DES: 2 speeds for smoke and heat exhaust

AXONE Micro III 1SP/DES is a pre-wired, NF-certified safety box used to control smoke and heat exhaust fans.
AXONE Micro III 1-speed/DES: 2 speeds for smoke and heat exhaust
AXONE Micro III 1-speed/DES: 2 speeds for smoke and heat exhaust
AXONE Micro III 1SP/DES is an NF-certified safety box used to control smoke and heat exhaust fans in non-residential buildings and industrial premises. Connected to the FACP between the main LV distribution board and the fan, it manages any faults with front panel display, stores the last five faults, activates the fan on instruction by the FACP, stops the fan and sets it to standby mode.
AXONE Micro III 1SP/DES provides a single fan speed for smoke and heat exhaust.
AXONE Micro III 1-speed/DES: 2 speeds for smoke and heat exhaust

The + products

  • version with built-in switch and pressure switch: ideal for box installed at less than 2 m from fan,
  • easy wiring,
  • storage and display of last five faults.

When instructed by the FACP, AXONE Micro III 1SP/DES activates the fan in smoke and heat exhaust mode. When instructed by the Fire service shutdown control, it stops the fan and sets it to “default” mode. Then, using the reset control, it changes to “standby” mode.

  • NF certified,
  • IP54 certified by an independent lab,
  • smoke and heat exhaust only,
  • for 1-speed 3-phase 400V or 230V motor, and single-phase 230V motor,
  • box available in 2 models,
  • insulation check on line “downstream” of box, factory setting 500 k,
  • “upstream” phase check: check phases are present and not inverted,
  • stores condition of box in case of power outage: box resumes initial state on return of power,
  • clear display of state and possible fault on front panel, without opening the box,
  • storage and display of last five faults.
  • Clear display of state and possible fault on front panel, without opening the box.
  • 2 versions:
    • basic box,
    • box with proximity switch and built-in pressure switch (IPDP) at 4.7A and 16.7A 3-phase 400V.
  • 2 mini-push buttons inside the box to perform a full cycle:
    • simulates a fire service shutdown order
    • simulates a reset order.
  • install the safety box near to the main LV distribution board or near the fan,
  • attach the box to the floor or the wall, preferably using the recommended flat roof base,
  • outdoors, use the flat roof base,
  • use the wall attachment brackets if the flat roof base is attached to a wall.

Products and accessories references

Documents

Showing 1 - y of document
  • Installation instructions - general - AXONE Micro III
    Manuals
    243 KB
  • Installation instructions AXONE Micro III 1 Speed smoke extraction Mono 230V
    Manuals
    287 KB
  • Installation instructions AXONE Micro III 1 Speed smoke extraction TRI 230V
    Manuals
    243 KB
  • Installation instructions AXONE Micro III 1 Speed smoke extraction TRI 400V 43,3/63/100A
    Manuals
    221 KB
  • Installation instructions AXONE Micro III 1 Speed smoke extraction TRI 400V 4,7A/16,7 A/25.4A
    Manuals
    240 KB
  • Installation instructions AXONE Micro III 2V/CONF : 2 Speeds "Confort + smoke extraction DAHLANDER 16,7/25,4/43,3/63,3/100 A
    Manuals
    225 KB