VEX300C
Air handling unit
The + products
- for suspended ceiling installation,
- very compact with high output,
- ultra quiet.
- EXact2, advanced control system,
- sliding or hinged doors,
- easy to install and maintain,
- low power consumption and efficiency at high temperature.
The VEX 300 C brings fresh, filtered air into the building and recovers heat from exhaust air using its high-efficiency heat exchanger. The incoming air can be heated and/or cooled using a comprehensive range of coils.
- 4 VEX300C models up to 1 490 m3/h,
- monobloc units,
- freestanding construction with double skinned panels,
- external finish: Aluzinc AZ185: corrosion class C4,
- 49 mm mineral wool insulation, density 65kg/m3,
- EN1886 values: D2, L2/L2, T2, TB3, F8,
- EC motor with high performance backward curved impeller,
- easy access & maintenance: sliding or hinge-mounted doors,
- choice of positioning of controls,
- highly efficient heat recovery heat exchanger (Eurovent AAHE),
- modulated Bypass,
- choice of filters for guaranteed air quality: flat ISO ePM10 50% (M5) or ISO ePM160% (F7) filters (ask us about other types of filter/pre-filter),
- Integrated switch,
-
EXact2 controls:
- constant speed,
- multi-speed,
- constant pressure,
- 0-10V.
-
configuration and monitoring via:
- wired remote control,
- option: Webserver and BMS communications via Modbus RTU / RS485, BACnet MSTP / BACnet IP protocols,
- option: Webserver and BMS communications via a bridge to Modbus TCP/IP or LON protocols.
- indoor (false-ceiling),
- circular spigots,
- right or left access.
References | Insulation density (kg/m³) | Thickness of insulation (mm) | Available filters | Max. Total efficiency (A-D) (%) | Efficiency level requirements | ECO efficiency level during optimal operating point | EC motor | Total pressure (Pa) | RPM during optimal operating point | Insulation material | Connection direction | Type of exchanger | Type of motor | Type of impeller |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
11058413 - VEX320C-1 | 65 |
50 |
flat ISO ePM10 50% (M5) or ISO ePM1 60% (F7) filters (ask us about other types of filter/pre-filter) |
0,601 |
62N (2015) |
78,7N |
Med motorcontroller (VSD) |
322 Pa |
2555 |
Ceiling |
With plates |
EC |
Backward curve |
|
11058414 - VEX320C-2 | 65 |
50 |
flat ISO ePM10 50% (M5) or ISO ePM1 60% (F7) filters (ask us about other types of filter/pre-filter) |
0,601 |
62N (2015) |
73,7N |
Med motorcontroller (VSD) |
733 Pa |
3735 |
Ceiling |
With plates |
EC |
Backward curve |
|
11058418 - VEX330C-1 | 65 |
50 |
flat ISO ePM10 50% (M5) or ISO ePM1 60% (F7) filters (ask us about other types of filter/pre-filter) |
0,601 |
62N (2015) |
78,7N |
Med motorcontroller (VSD) |
322 Pa |
2555 |
Ceiling |
With plates |
EC |
Backward curve |
|
11058419 - VEX330C-2 | 65 |
50 |
flat ISO ePM10 50% (M5) or ISO ePM1 60% (F7) filters (ask us about other types of filter/pre-filter) |
0,601 |
62N (2015) |
73,7N |
Med motorcontroller (VSD) |
733 Pa |
3735 |
Ceiling |
With plates |
EC |
Backward curve |
References | A (mm) | B (mm) | C (mm) | E (mm) | F (mm) | Ø connection (fresh air or exhaust) (mm) | Ø connection (discharge or air supply) (mm) | Weight (kg) |
---|---|---|---|---|---|---|---|---|
11058413 - VEX320C-1 | 995 |
440 |
1135 |
1385 |
540 |
315 |
315 |
128 |
11058414 - VEX320C-2 | 995 |
440 |
1135 |
1385 |
540 |
315 |
315 |
131 |
11058418 - VEX330C-1 | 1505 |
440 |
1135 |
1385 |
540 |
315 |
315 |
178 |
11058419 - VEX330C-2 | 1505 |
440 |
1135 |
1385 |
540 |
315 |
315 |
181 |
References | Minimum airflow | Airflow (m³/h) | Max. airflow (m³/h) |
---|---|---|---|
11058413 - VEX320C-1 | 1.005 m³/h |
680 |
|
11058414 - VEX320C-2 | 90 |
1.355 m³/h |
1260 |
11058418 - VEX330C-1 | 135 |
1.005 m³/h |
900 |
11058419 - VEX330C-2 | 135 |
1.355 m³/h |
1490 |
References | Max. exchanger output (%) | Max. current absorbed (kW) |
---|---|---|
11058413 - VEX320C-1 | 94 |
3,1 |
11058414 - VEX320C-2 | 94 |
5,3 |
11058418 - VEX330C-1 | 97 |
3,1 |
11058419 - VEX330C-2 | 97 |
5,3 |
References | Frequency (Hz) | Protection rating | Max. current consumption SINGLE-PHASE 230 V (A) | Max. electrical output of unit (kW) | Unit voltage (V) |
---|---|---|---|---|---|
11058413 - VEX320C-1 | 50 |
IP20 |
3,1 |
0,6 |
230 |
11058414 - VEX320C-2 | 50 |
IP20 |
5,3 |
1,2 |
230 |
11058418 - VEX330C-1 | 50 |
IP20 |
3,1 |
0,6 |
230 |
11058419 - VEX330C-2 | 50 |
IP20 |
5,3 |
1,2 |
230 |
- Text ErP - Ventilation : Complies with eco-design regulation 1253/2014 and energy labelling regulation 1254/2014 for ventilation. Energy classes:
- Eligibility for EEC : Yes
- ESC data sheet no. 1 : BAT-TH-126
Test values as per standard EN 1886 |
---|
D1, L1, L1, F9, T2, TB3 |