VEX200 Air handling unit

VEX200

Air handling unit

VEX200 is an energy-efficient air handling unit with rotary heat exchanger and  ALC™ technology, which ensures the best indoor air quality without compromise.
VEX200
Download CAD Library file
VEX200
VEX200 is a range of energy-friendly air handling units with rotary heat exchangers and EC motors. You can choose between two rotor types, standard and high efficiency. Choose ALC™ when you want to ensure a good indoor climate. ALC™ allows you to transfer humidity while eliminating recirculation of particles, aerosols, viruses, etc. The many versions of the VEX200 range permit a high level of flexibility in installation and location as you can choose spigot location in the units end, top and bottom.

The units are delivered with integrated control systems, that are accessed via the connection box on the front of the air handling unit.

VEX200 air handling units are supplied either as a complete air handling units (VEX240-250) or sectional units (VEX260--280).
VEX200

The + products

  • Available as indoor and outdoor model
  • Optimal air quality and thermal comfort
  • Very low noise level
  • Energy savings * Easy installation and maintenance

The VEX 200 brings fresh, filtered air into the building and recovers heat from exhaust air using its high-efficiency heat exchanger. The incoming air can be heated and/or cooled using a comprehensive range of coils.

  • The ALC™ (Automatic Leakage Control) option is the patented solution that prevents the propagation of viruses by air handling units equipped with rotary heat exchangers. It measures, checks and constantly adjusts the pressure difference between supply and return airflows to ensure that no stale air comes into contact with the clean air produced by the unit.
  • Monoblock or multi-block units depending on the model.
  • Self-supporting construction with dual-wall panels.
  • External finish in Aluzinc AZ185: class 4 anti-corrosion performance.
  • 49 mm mineral wool insulation (class A1 as per DIN4102), 65 kg/m³ density.
  • EN 1886 values: D2, L2/L2, T2, TB3, F8, F9
  • Configurable connections.
  • EC motor and Exstream high-performance backward curve impeller,
  • Easy to access and maintain: components mounted on slides, adjustment accessible via a specific central hatch.
  • 2 choices of efficiency on rotary exchanger (Eurovent AARE) with optional drain zone to preserve indoor air quality.
  • 4 choices of exchanger types on request:
  • standard aluminium exchanger,
  • hygroscopic,
    • sorption: ideal for hot and humid climates,
    • epoxy: ideal for corrosive atmospheres (saline).
  • Choice of filters to guarantee air quality: flat filters or M5 bag filters (ePM10 50%) and F7 (ePM1 65%) - consult us for other types of filters and pre-filters.
  • Built-in switch
  • EXact2 controller:
    • constant speed,
    • multi-speed,
  • constant pressure,
    • 0-10 V.
  • Configuration & monitoring via:
    • wired remote control,
    • option: Webserver and BMS communication via Modbus RTU / RS485, BACnet MSTP / BACnet IP protocols,
    • option: Webserver and BMS communication via a gateway supplied to Modbus TCP-IP or LON protocols.
  • Flexible connection to duct system with automatic leakage control (ALC™):
    • Horizontal, top and bottom
  • Compact design for small rooms – available as a unit or optionally as a SPLIT unit
  • equipment rooms / terraces,
  • indoors / outdoors,
  • in-line duct connection or choice of two vertical fixings,
  • connection via circular or rectangular fixings, depending on model,
  • choice of left or right side for equipment fittings.
References Insulation density (kg/m³) Thickness of insulation (mm) Rotary stepper motor - Phase current Rotary stepper motor - Power consumption Rotary stepper motor - Over-current protection Rotary stepper motor - Control (built in rotation monitor) Voltage input Motor class in accordance with IEC TS 60034-30-2 Current overload protection Regulation Control signal with control system Control signal with third party control system Fluid temperature (air) Max. Total efficiency (A-D) (%) Efficiency level requirements ECO efficiency level during optimal operating point EC motor Total pressure (Pa) RPM during optimal operating point Conditions Insulation material Connection direction Type of exchanger Type of motor Type of impeller Ambient temperature range Rotordrev stepmotor, regulering
11058005 - VEX240

65

50

0,2

45

Indbygget

230

1 x 230

IE5 (Ultra Premium Efficiency)

Indbygget

Trinløs via motorstyring (MC)

Modbus

0 - 10 V DC

-40°C....+40°C

58,1

62N (2015)

76,2N

Med motorcontroller (VSD)

617

2886

  • Density = 1.2 kg/m3- Pressure ratio < 1.11- other points in acc. with EC327/2011 (see product instructions)

Horizontal

Counterflow

EC

Backward curve

-30°C....+50°C

Rotor rotation variable on a 0–10 rpm scale

11058006 - VEX250

65

50

0,2

45

Indbygget

230

1 x 230

IE5 (Ultra Premium Efficiency)

Indbygget

Trinløs via motorstyring (MC)

Modbus

0 - 10 V DC

-40°C....+40°C

60

62N (2015)

74,4N

Med motorcontroller (VSD)

826

2902

  • Density = 1.2 kg/m3- Pressure ratio < 1.11- other points in acc. with EC327/2011 (see product instructions)

Horizontal

Counterflow

EC

Backward curve

-30°C....+50°C

Rotor rotation variable on a 0–10 scale

11058007 - VEX260

65

50

0,2

45

Indbygget

230

1 x 230

IE5 (Ultra Premium Efficiency)

Indbygget

Trinløs via motorstyring (MC)

Modbus

0 - 10 V DC

-40°C....+40°C

57,1

62N (2015)

67,2N

Med motorcontroller (VSD)

1065

3078

  • Density = 1.2 kg/m3- Pressure ratio < 1.11- other points in acc. with EC327/2011 (see product instructions)

Horizontal

Counterflow

EC

Backward curve

-30°C....+50°C

Rotor rotation variable on a 0–10 scale

11058008 - VEX270

65

50

0,2

45

Indbygget

230

3 x 400

IE5 (Ultra Premium Efficiency)

Indbygget

Trinløs via motorstyring (MC)

Modbus

0 - 10 V DC

-40°C....+40°C

60,4

62N (2015)

66,6N

Med motorcontroller (VSD)

1396

2913

  • Density = 1.2 kg/m3- Pressure ratio < 1.11- other points in acc. with EC327/2011 (see product instructions)

Horizontal

Counterflow

EC

Backward curve

-30°C....+50°C

Rotor rotation variable on a 0–10 scale

11058009 - VEX280

65

50

0,2

45

Indbygget

230

3 x 400

IE5 (Ultra Premium Efficiency)

Indbygget

Trinløs via motorstyring (MC)

Modbus

0 - 10 V DC

-40°C....+40°C

60,4

62N (2015)

66,6N

Med motorcontroller (VSD)

1396

2913

  • Density = 1.2 kg/m3- Pressure ratio < 1.11- other points in acc. with EC327/2011 (see product instructions)

Horizontal

Counterflow

EC

Backward curve

-30°C....+50°C

Rotor rotation variable on a 0–10 scale

VEX200 VEX200
References A (mm) A1 (mm) A2 (mm) B (mm) C (mm) Ø connection (fresh air or exhaust) (mm) Ø connection (discharge or air supply) (mm) Weight (kg) Tilslutning horisontalt mål (mm) Tilslutning vertikalt mål (mm) Vægt for indtransport
11058005 - VEX240

1490

   

860

1155

315

315

260

   

200 kg (ekskl. låger og ventilatorer)

11058006 - VEX250

1600

   

945

1205

400

400

273

   

195 kg (ekskl. låger og ventilatorer)

11058007 - VEX260

1820

710

400

1265

1675

   

525

800

400

Ventilatorsektioner: 2 x 117 kg, Rotorsektion: 127,5 kg

11058008 - VEX270

2050

825

400

1525

1905

   

750

1000

500

Ventilatorsektioner: 2 x 170,5 kg, Rotorsektion: 187 kg

11058009 - VEX280

2160

880

400

1900

2205

   

1102

1400

600

Ventilatorsektioner: 2 x 236 kg, Rotorsektion: 221 kg

References Minimum airflow Max. airflow ErP (m³/h) Airflow (m³/h) Max. airflow (m³/h)
11058005 - VEX240

370

2090

2286

2420

11058006 - VEX250

720

2825

3279

3730

11058007 - VEX260

1200

4370

4551

5540

11058008 - VEX270

1400

7020

7186

8910

11058009 - VEX280

2800

12615

7186

18425

References Max. exchanger output (%) Max. current absorbed (kW)
11058005 - VEX240

90

12,5

11058006 - VEX250

90

11,2

11058007 - VEX260

90

18

11058008 - VEX270

90

17

11058009 - VEX280

90

30,5

References Frequency (Hz) Max. current consumption SINGLE-PHASE 230 V (A) Max. current consumption THREE-PHASE 400 V (A) Max. electrical output of unit (kW) Voltage (V) Unit voltage (V) Maximum current - unit (A) Power consumption (kW) Max current of zero (A)
11058005 - VEX240

50

12,5

 

1,8

1x230

230

12,5

0.674

 
11058006 - VEX250

50

 

11,2

2,9

3x400

400

11,2

1.253

15

11058007 - VEX260

50

 

18

5,0

3x400

400

18

2.359

23,5

11058008 - VEX270

50

 

17

9,3

3x400

400

17

4.619

 
11058009 - VEX280

50

 

30,5

17,6

3x400

400

30,5

17.6

 
  • Text ErP - Ventilation  :  Complies with eco-design regulation 1253/2014 and energy labelling regulation 1254/2014 for ventilation. Energy classes:
  • Eligibility for EEC  :  Yes
  • ESC data sheet no. 1  :  BAT-TH-126
Test values as per standard EN 1886 Ventilation energy class - Average climate

D2, L1, L1, F9, T2, TB3

A

Products and accessories references

  • VEX240
    VEX240
    11058005
    Nous consulter
  • VEX250
    VEX250
    11058006
    Nous consulter
  • VEX260
    VEX260
    11058007
    Nous consulter
  • VEX270
    VEX270
    11058008
    Nous consulter
  • VEX280
    VEX280
    11058009
    Nous consulter

Documents

Showing 1 - y of document
  • VEX200 Declaration of Conformity
    Conformities
    127 KB
  • IHM Remote control User Manual
    Manuals
    4 MB
  • VEX200 Electrical installation guide
    Manuals
    3 MB
  • VEX200 Installation instructions
    Manuals
    2 MB

1 software